Run electrical wires underground to reach sheds, lights, patios, and other locations following safe wiring practices. We show the easiest way, using rigid conduit.

By the DIY experts of The Family Handyman Magazine

Electrical Wiring: How to Run Power Anywhere

Run electrical wires underground to reach sheds, lights, patios, and other locations following safe wiring practices. We show the easiest way, using rigid conduit.

By the DIY experts of The Family Handyman Magazine

Overview: Project scope, special tools, materials and costs

Dragging extension cords across the yard to power the weed whip, fumbling around in a dark shed...most of us take these hassles for granted. But it doesn't have to be that way. With a day's work, you can run electrical lines to any part of your yard. This article will show you how to bring power to a shed, but the process is almost identical if you want to simply mount an outlet on a post planted in the soil. A licensed electrician would charge at least several hundred dollars plus materials to run lines from your house to a shed 50 ft. away (not including any work inside your house). You can do the job yourself for a materials cost of about $140.

We'll show you how to run wires through rigid metal conduit (RMC). This method offers the best protection of the wiring and requires the least amount of digging. It also lets you install a GFCI outlet at the end of the line rather than at the house, which means you'll never have to run back to the house to reset a tripped GFCI. For information on completing the wiring inside the outbuilding or connecting to power in your house, type “wiring” in the search box above.

If you want to provide a dedicated circuit to the shed, hire an electrician to make the final connection in your main electrical panel. Otherwise you can connect to an existing circuit if the circuit has enough capacity and the box you're connecting to has enough volume for the additional wires.

To run the wires inside rigid conduit, you'll need a hacksaw, a pipe bender capable of bending 1/2-in. rigid conduit with an outside diameter of 3/4 in. (about $30), and a fish tape long enough to reach through the buried pipe ($15 to $60). You'll also need a pair of pipe wrenches to screw the sections of pipe together, a drill and 1-in. bit capable of penetrating your siding, and wire cutting and stripping tools. The total cost of this project is typically about $2.20 for every foot of buried conduit, plus about $25 for LB fittings and miscellaneous hardware.

A few weeks before you start the project, contact your local building department to obtain an electrical permit if one is required. Then a few days before you dig, call 811 to have your underground utility lines marked. Learn more at call811.com.

Figure A: Cable depth

Metal Conduit Means Less Digging

Running wires inside rigid metal conduit (RMC) is a little more expensive than burying underground feeder cable (UF), but it saves labor. That's because the top edge of RMC has to be only 6 in. below the surface of the ground, while UF must be buried 12 in. deep (deeper in some situations). That extra 6 in. of trench depth may not seem like a big deal, but it adds hours of backbreaking work, especially if you have rocky soil, hard clay or lots of tree roots.

Step 1: Plan the conduit route and dig the trench

There are several factors to consider in planning the route from the house to the shed. Obviously the shorter the trench, the less digging you'll have to do, but you also have to determine where you're going to connect to power inside the house and how easy it will be to get there. In some cases, a little more digging could save you from having to tear into a basement ceiling. Start by locating a power source, whether it's your main panel, a ceiling box, outlet or other electrical box. Then figure out the best spot for the new conduit to enter the house. Since the National Electrical Code (NEC) limits the number of bends you can make in the pipe to a total of 360 degrees, you have to plan the route carefully. The two 90-degree bends from the ground into the house and shed consume 180 degrees, leaving you 180 degrees more for any additional bends.

With the route planned, you can measure for the amount of wire and conduit you need and head to the hardware store or home center. Add 10 ft. to the length of wire and pipe to make sure you'll have enough.

It's smart to drill the hole into the house before you start digging just in case you run into an obstacle and have to choose a new location. When you're sure of the exit point, dig a trench from the house to the shed. If you're going across a lawn, remove a slice of sod the width of a spade from the surface and set it aside to reuse after you bury the pipe. Then use a mattock or narrow spade to dig the trench (Photo 1). Pile the dirt on plastic tarps so you don't have to rake it out of the grass later.

Step 2: Mount the LBs and metal boxes

The rigid conduit will come out of the ground and into a fitting called an “LB.” The LB has a removable cover that simplifies the task of pulling wire by eliminating a sharp right-angle turn. The trickiest part of this project is mounting the LBs and connecting them to metal boxes inside the house and shed. In general, you'll have to choose a box location and then calculate the length of electrical metallic tubing (EMT) needed to reach from the back of the LB to the box. If you're going into a basement or crawl space, the length of the conduit usually isn't critical. Start by drilling a small hole with a long bit to make sure you're in the right spot. Then drill a 1-in. hole for the LB and conduit. Screw a 1/2-in. conduit connector into the back of the LB and then attach a piece of 1/2-in. EMT that's long enough to reach an easily accessible box in the basement or crawl space. After you've mounted the LB to the siding, go inside and add a conduit connector and a metal electrical box to the other end of the EMT. This box is where you'll make the connections from your house wiring to the new shed wiring.

On the inside of the shed, you'll screw a 4 x 4-in. square metal box to the side of the stud. Then connect the LB to the box using the parts shown in Figure B.

Figure B: Through-the-wall parts

Figure B: Through-the-Wall Parts

Running the conduit through the wall to an inside box is the most difficult step.

Step 3: Run the metal conduit

The 10-ft. lengths of RMC are threaded on both ends and include a coupling on one end. You'll start by bending the first pipe and threading an LB onto the end. Then thread the pipes together one at a time until you reach the other end, where you'll cut and bend the last piece of conduit to fit and connect it to the LB with a compression connector. Photos 1 – 6 show the process.

Temporarily attach the LB to the shed and measure between it and the bottom of the trench (Photo 2). Add 3/4 in. for the threads that'll go into the LB and subtract the bending allowance listed on your bender (usually 6 in.) from this measurement for the bend. Mark this length on a piece of conduit, measuring from the end with bare threads. Then find a level spot to bend the conduit. Align the mark on the conduit with the arrow on the bender. Push with your foot and pull back on the pipe handle to bend the pipe (Photo 3). Use a level or the bubble built into some benders to tell when you reach 90 degrees. Take the bent conduit back to the trench and screw the LB onto the end. Photo 4 shows how to connect lengths of conduit until you reach the house.

Bend the last piece of conduit up and cut it off to fit into the compression connector (Photos 5 and 6). Start by measuring from the last piece of conduit to the house wall (Photo 5). If the LB is held away from the wall by siding, subtract this distance from the measurement. Then add 3/4 in. for the threading and subtract for the bend. Mark the last piece of conduit, starting from the bare threads. Once again, place the bender arrow on the mark and bend the conduit. Face the threaded end of the conduit when you make this bend, not the end with the coupling. Mark the conduit (Photo 6) and cut it with a hacksaw. Remove burrs from the inside of the pipe by smoothing with a file or by inserting the bare metal handles of pliers into the pipe and twisting. Complete the conduit run by threading on the last piece of conduit. You'll have to lift the previous piece of conduit to create clearance as you spin the bent pipe around. Finally, slip the end of the conduit into the compression connector and tighten the compression nut with a wrench. Wrap a conduit strap around the conduit and screw it to the house to secure the conduit. Also press a rope of “duct seal” around the top of the LB to keep water out.

Step 4: Pull and connect the wires

Remove the covers from the LBs and push a fish tape through the conduit. Then pull the wire through the conduit (Photos 7 and 8). You'll need two wires, one white and one black, for one circuit, or more if you intend to wire a three-way switch from the house or add more than one circuit. Use THWN-2 14-gauge stranded wire if you get power from a 15-amp circuit or THWN-2 12-gauge stranded wire for a 20-amp circuit. Leave enough extra wire on each end to reach the inside metal box plus 12 in.

The NEC requires a means, such as a single-pole switch, to disconnect the power where it enters the shed. Photo 9 shows how to connect the switch, ground wire and neutral wires. Run wires from the switch to a GFCI receptacle, and from there to the rest of the outlets or lights in your shed.

Back to Top

Required Tools for this Project

Have the necessary tools for this DIY project lined up before you start—you’ll save time and frustration.

    • Tape measure
    • 4-in-1 screwdriver
    • Drill/driver, cordless
    • Torpedo level
    • Drill bit set
    • 1-in. drill bit
    • Hacksaw
    • Pipe wrenches, 2
    • Pliers
    • Spade
    • Wire stripper/cutter

You'll also need a mattock, pipe bender, fish tape, and leather gloves.

Required Materials for this Project

Avoid last-minute shopping trips by having all your materials ready ahead of time. Here's a list.

    • RMC (rigid metal conduit)
    • EMT (electrical metallic tubing)
    • Fittings (connectors, LBs)
    • Electrical boxes
    • Stranded electrical wires, 2 (white and black)
    • Wire connectors
    • Conduit straps
    • Duct seal
    • Electrical tape
    • Switch
    • GFCI

Comments from DIY Community Members

Share what's on your mind and see what other DIYers are thinking about.

1 - 4 of 4 comments
Show per page: 20   All

September 27, 4:16 PM [GMT -5]

It's really important to stress, that installing electrics aren't just a case of picking the cable from the van and throwing it in. Depending on the distance from the property and the loading the circuit will need to be designed, there's a difference between a single light and a freezer in a small 6x4 close to the house, than a garden office with computers, lighting and heating 200ft from the house. We have also been involved in projects for garden gyms, saunas, spas and hot tubs.

All works in the garden, kitchen and bathroom are classed as special locations under BS7671, so work must be carried out by a qualified, insured and licenced electrician and submitted to the local authority for approval.

Jamie Morgan MIET BMEI
Electrical Engineer
ESI: Electrical Engineers & Contractors Ltd
Www.esielectrical.co.uk

September 27, 4:16 PM [GMT -5]

It's really important to stress, that installing electrics aren't just a case of picking the cable from the van and throwing it in. Depending on the distance from the property and the loading the circuit will need to be designed, there's a difference between a single light and a freezer in a small 6x4 close to the house, than a garden office with computers, lighting and heating 200ft from the house. We have also been involved in projects for garden gyms, saunas, spas and hot tubs.

All works in the garden, kitchen and bathroom are classed as special locations under BS7671, so work must be carried out by a qualified, insured and licenced electrician and submitted to the local authority for approval.

Jamie Morgan MIET BMEI
Electrical Engineer
ESI: Electrical Engineers & Contractors Ltd
Www.esielectrical.co.uk

June 10, 11:55 PM [GMT -5]

Yep, I've seen it too. In fact, was on a job where we did it. Worked perfectly. We wadded up a small piece of cloth...it went thru 300 feet of conduit in no time. Pulling the wires took a bit longer.

Also, an alternative to buying or renting the bender is:
make a fixture on the work bench with some 2x lumber...may take a few tries to get it right but kind of neat.
-or- use right angle fixtures...

March 05, 7:51 PM [GMT -5]

I've seen electricians use a spool of heavy string for long stretches of conduit. They fasten a ball of cotton or a rag to the end of the string, stuff it in the conduit, and shop vac it through the conduit. Then they fasten the wire to the string and pull the wire through.

+ Add Your Comment
closeX

Add Your Comment

Electrical Wiring: How to Run Power Anywhere

Please add your comment
closeX

Log in to My Account

Log in to enjoy membership benefits from The Family Handyman.

  • Forgot your password?
Don’t have an account yet?

Sign up today for FREE and become part of The Family Handyman community of DIYers.

Member benefits:

  • Get a FREE Traditional Bookcase Project Plan
  • Sign up for FREE DIY newsletters
  • Save projects to your project binder
  • Ask and answer questions in our DIY Forums
  • Share comments on DIY Projects and more!
Join Us Today
closeX

Report Abuse

Subject
Reasons for reporting post

Free OnSite Newsletter

Get timely DIY projects for your home and yard, plus a dream project for your wish list!

Follow Us